38 | BEKO TECHNOLOGIES GMBH
Dryer Operating pressure
Model 4 bar 7 bar 10 bar 13 bar 16 bar
AC119 11 08 075 07 065
AC122 12 10 08 075 07
AC126 13 11 09 085 08
AC136 15 13 11 10 09
AC148, AC191 20 15 13 12 12
AC171, AC196 28 20 16 14 14
13.3 Purge plug identification
The table below shows the purge plug fitted to all models across the range of operating
pressures.
14. Environmental Conditions
All dryers are designed to be safe under the following conditions:
• Indoor use
• Altitude up to 2000m
• Ambient temperature 5°C to 40°C
• Maximum RH 80% for temperatures up to 31°C, decreasing linearly to 50% RH at
40°C
• Mains supply voltage fluctuations not to exceed +/- 10% of nominal
• Transient over voltage IEC664 Class II
• Pollution degree 2, IEC 664
For operation extended from the above conditions, please contact BEKO.
15. Warranties and liability
Claims for warranty and liability concerning personal injury or material damage are
excluded if they resulted due to one or more of the following factors:
• Inappropriate use or application of the dryer.
• Technically incorrect installation, startup operation or maintenance of the dryer.
• Operation of a known damaged dryer.
• Failure to observe the information given in this manual concerning all life phases of
the dryer.
• Undertaking constructional or operational modifications to the dryer without prior
agreement with BEKO.
• Inadequate monitoring and replacement of components of the dryer that are subject
to wear or consumable.
• Improper completion of repairs.
• Use of non-original or non-approved parts for service or maintenance.
Comentarios a estos manuales